Weelko Monopolar Radiofrequency WKB003 for professional facial and body aesthetic treatments
Professional CE marking
The Weelko WKB003 monopolar radiofrequency is a professional aesthetic device with a touch screen, designed for non-invasive facial and body aesthetic treatments aimed at improving skin firmness, skin texture and the overall appearance of the tissue.
It works with monopolar radiofrequency technology and a return plate, allowing controlled application on the face and body using three specific probes: body, facial and eye contour.
Digital monopolar radiofrequency device. Designed for professional use in the treatment room, with a frequency of 0.5 MHz, 7-inch touch screen and three working heads.
Main features
- Monopolar radiofrequency technology with return plate for deep, controlled action.
- Includes three interchangeable heads: body, facial and eye contour.
- Colour touch screen with intuitive menus and configurable protocols.
- Power, time and intensity adjustment according to the treatment area and the client’s tolerance.
- Facial or body treatment selection from the device interface.
- Emission mode with three wave types: continuous, pulsed and combined.
- Facial and body aesthetic use for firming protocols, improving the appearance of the skin and treating aesthetic skin laxity.
What the device includes
- 1 body probe
- 1 facial probe
- 1 eye probe
- 1 return plate
- 1 main unit
- 1 connection / power cable
Technical data
- Model WKB003
- Brand Weelko
- Line HighTech Smooth
- Technology Monopolar radiofrequency
- Frequency 0.5 MHz / 500 kHz
- Working power 160 W
- Rated power 140 W
- Input voltage 200-240 V
- Electrical frequency 50/60 Hz
- Screen 7-inch touch screen
- Body probe 7 cm
- Facial probe 4 cm
- Eye probe Cone shape
- Console size 34 x 38 x 15 cm
- Packaging size 51 x 45 x 22 cm
- Net weight 8 kg
- Gross weight 9 kg
- Warranty 1 year
- Certification CE
- Energy efficiency class C
Compliance and directives
The device complies with the European directives indicated by the manufacturer:
- Low voltage 2014/35/EU
- Electromagnetic compatibility 2014/30/EU
Detailed product description
The Weelko Monopolar Radiofrequency works by generating controlled heat in the deeper layers of the dermis. This thermal stimulus promotes the activation of collagen and elastin, contributing to skin with an improved appearance, greater firmness and enhanced visible elasticity.
The result is a progressive improvement in skin tone, a smoother appearance and a more even skin feel. In body protocols, it is used as an aesthetic complement to improve the appearance of skin with laxity and uneven texture.
It is a complete solution for beauty salons looking to incorporate non-invasive facial and body treatments for aesthetic firming and visible improvement of skin quality.
How monopolar radiofrequency works
This device works at 0.5 MHz and uses an active electrode together with a return plate to close the circuit during application. The energy is transmitted from the handpiece to the plate, concentrating the work on the treated area.
Monopolar technology allows rapid heating and deep work on aesthetic tissue, making it suitable for facial and body firming protocols carried out by professionals.
Performance in the treatment room
- Facial treatment with medium probe and eye probe.
- Body treatment with large probe.
- Aesthetic application on areas of different sizes with intensity control.
- Customisable protocols according to area, time and thermal tolerance.
- Immediate energy diffusion through active handpiece and return plate.
Ease of use
The interface guides the professional step by step, with direct access to the mono.face and mono.body modes. The menu allows intensity, time and wave type to be adjusted from the touch screen.
The heads are lightweight and easy to handle, designed for continuous work in the treatment room. The return plate is easy to position and helps maintain stable application during the session.
Working modes
- Mono.face For facial radiofrequency and eye contour
- Mono.body For body radiofrequency
- Mode Allows selection of the wave type: continuous, pulsed or combined
- Level Intensity adjustment across 10 levels
- Time Treatment time setting. The default programme is 30 minutes
- Play/Pause Start or pause the treatment
Wave types
Continuous
Indicated for large areas, with constant emission and greater heat generation.
Pulsed
Indicated for smaller or more delicate areas, with lower emission and more moderate heat. It is also suitable for areas where bone tissue is more prominent.
Combined
Intermediate option between continuous and pulsed emission.
Facial aesthetic indications
- Mild or moderate facial skin laxity on the face, neck and décolleté.
- Skin firming.
- Aesthetic work on the eye contour, mouth contour, forehead, cheekbones, chin, double chin, neck and décolleté, always respecting mucous membranes and eyes.
- Improvement in the appearance of the facial contour.
- Visible improvement in expression lines and wrinkles.
- Improvement in the appearance of dull skin or skin lacking radiance.
- Improvement in skin texture and the appearance of superficial marks.
- Improvement in the appearance of under-eye bags and dark circles from a purely aesthetic approach.
- Cosmetic work on skin lacking tone and visible elasticity.
Body aesthetic indications
- Improvement of visible firmness on the abdomen, arms, legs and buttocks.
- Improvement in the appearance of skin with uneven texture.
- Aesthetic complement in cavitation and body contouring protocols.
- Improvement of skin tonicity.
- Aesthetic work on stretch marks and visible skin marks from a cosmetic approach.
- Support in protocols aimed at improving the appearance of orange peel skin.
- Aesthetic application on large areas with progressive thermal control.
Benefits in aesthetic treatments
- Provides highly requested facial and body firming treatments.
- Helps promote the appearance of firmer, more even skin.
- Contributes to improving the appearance of expression lines and aesthetic skin laxity.
- Can be integrated into professional facial and body treatment room protocols.
- Non-invasive device that is comfortable for the client when used correctly.
- Allows the salon’s service menu to be expanded with versatile technology.
General usage protocol
- Connect the power cable to the rear panel.
- Correctly connect the probes and the return plate to the rear panel.
- Switch on the device using the front button and press the Weelko logo on the screen to access the menu.
- Select mono.face for the facial and eye probe, or mono.body for the body probe.
- Apply specific radiofrequency gel or glycerine in sufficient quantity to the skin before placing the probe.
- Adjust the intensity from the LEVEL menu.
- Select the working time from TIME.
- Choose the wave type from MODE.
- Press PLAY/PAUSE to start or pause the session.
Indicative facial aesthetic protocol
- Carry out a prior assessment of the skin condition.
- Remove make-up, creams, oils and sunscreen before the session.
- Ensure that the client is not wearing metal items near the treatment area.
- Apply glycerine or a conductive product suitable for radiofrequency.
- Move the handpiece constantly, quickly and upwards, without leaving it fixed on the skin.
- Always work with a comfortable thermal sensation for the client, increasing the intensity progressively.
- Indicative facial session duration: 10 minutes, with a maximum of 20 minutes depending on the area and professional judgement.
- Indicative frequency: 5 to 10 sessions, between 1 and 3 times per week, depending on the planned aesthetic protocol.
- At the end, complement with moisturising or soothing cosmetics, or a suitable mask.
Indicative body aesthetic protocol
- Carry out a prior assessment of the body area to be treated.
- Apply enough transparent conductive gel or vegetable glycerine.
- Keep the handpiece in contact with the skin at all times.
- Perform constant movements, preferably upwards on the legs and following the natural direction of body aesthetic work.
- Do not leave the head fixed on the same point to avoid excess heat.
- Recommended time per area: up to 20 minutes. Do not extend treatments beyond 60 minutes in total.
- Depending on the size of the area, times may be professionally adjusted.
- The indicative number of sessions for body protocols is between 5 and 10 sessions, always reassessing the client’s aesthetic progress.
Care before and after the session
- The skin must be properly cleansed before treatment.
- Good skin hydration and adequate water intake are recommended in cosmetic protocols.
- After the facial session, applying sun protection is recommended.
- Maintain daily skincare routines appropriate to the skin type.
- In the event of temporary redness, burning or mild irritation, allow the area to rest and assess whether to continue the protocol.
- Avoid excessive temperatures during the session, as they may compromise comfort and the desired aesthetic result.
Safety and maintenance
The device incorporates intensity control and time settings for professional and safe application. Its compact structure and removable accessories make daily maintenance in the treatment room easier.
- Clean the probes with a damp cloth after each treatment.
- Do not use the device in damp or poorly ventilated environments.
- Do not use the device outdoors.
- If the power cable is damaged, it must be replaced by qualified personnel.
- Do not open or inspect the internal components of the device.
- The appearance of the product and some components may vary without prior notice from the manufacturer.
Precautions for use
- The return plate must be in contact with the skin during application.
- The electrode must be moved constantly with continuous circular or gliding movements.
- Never leave the electrode fixed in a single area.
- Check during the session that the intensity is suitable and comfortable for the client.
- The professional and client must remove metal objects during the treatment.
- The professional is advised to wear insulating gloves during application.
- The eye probe shares the connection with the facial probe, so to use one, the other must be disconnected.
- Do not forget to apply a sufficient amount of conductive product before starting work.
Contraindications and usage exclusions
- Do not use during pregnancy or breastfeeding.
- Do not use on people with pacemakers or other implanted electrical devices.
- Do not use on people with serious heart disease.
- Do not use on people with coagulation disorders.
- Do not use on people with connective tissue diseases.
- Do not use on people with neurological or neuromuscular diseases.
- Do not use on people with cancer, HIV or diabetes without prior assessment by a competent professional.
- Do not use on skin with infections, wounds, active irritation, psoriasis, dermatitis or unassessed skin conditions.
- Do not work on areas with altered sensitivity to heat.
- Do not apply over areas with metal objects, metal prostheses in the treatment area or permanent make-up/facial tattoos without prior assessment.
- Do not apply on skin recently subjected to aggressive procedures, deep chemical peeling, burns or recent surgery.
- Do not use on people with Cushing’s syndrome.
- Do not work over the thyroid.
- Take care in areas with injected fillers; after recent infiltrations of hyaluronic acid, botox or other products, a prudent waiting period should be observed before treatment.
- Do not use on recently shaved or waxed skin if sensitivity or visible irritation is present.
- In the case of a history of keloids, fever, infectious processes or use of anticoagulants, immunosuppressants or corticosteroids, assess the suitability of the protocol before the session.
Benefits for your business
- Allows you to incorporate high-demand facial and body treatments into professional aesthetics.
- Device that is easy to implement in the treatment room and suitable for intensive use.
- Versatility thanks to its three working probes.
- Simple configuration via touch screen.
- Good balance between functionality, compact size and professional performance.
Additional technical information
- For the treatment, it is recommended to use a specific glycerine gel, avoiding the use of very watery conductive gel when it may excessively increase thermal transmission.
- The recommended duration indicated by the manufacturer is 10 minutes for facial treatments and 20 minutes for body treatments. In any case, a total time of 60 minutes must not be exceeded.
- Do not leave the electrode fixed on the same area. Application must be performed with continuous movement to avoid excess heat on the skin.
- Before each session, the professional and client must remove metal objects from the treatment area.
- When the recycling symbol appears on the device or its packaging, the product must not be disposed of as conventional household waste. It must be managed in accordance with local regulations applicable to electrical appliances.
This device is intended exclusively for professional use in beauty salons. Its operation requires specific technical training. Sunmarket Wellness accepts no responsibility for use by people without the appropriate qualification.
The return plate must remain in contact with the skin during application and the handpiece must always be kept moving to avoid excess heat.
Do not use during pregnancy or breastfeeding, on people with pacemakers or other implanted devices, or on skin with infections, wounds, active irritation or recent surgery.
The eye probe shares the connection with the facial probe, so to use one, the other must be disconnected.
The appearance of the product and some components may vary without prior notice from the manufacturer.