Weelko HighTech Smooth WKB003 monopolar radiofrequency device
The Weelko HighTech Smooth WKB003 is a digital monopolar radiofrequency device for professional beauty cabins, designed for facial and body treatments within non-invasive beauty protocols. Its compact design, 7-inch touchscreen and programme selection from the control panel make operation clear and practical in beauty centres, aesthetic clinics and wellness spaces.
The system works at 0.5 MHz and includes different probes to adapt the application to body areas, facial zones and the eye contour. The included return plate is part of the operating circuit required for monopolar radiofrequency, so it must be used in accordance with the device’s professional protocol.
Digital device with touchscreen
HighTech Smooth WKB003 allows the user to select the working mode from its interface: facial radiofrequency or body radiofrequency. The screen is used to adjust operating parameters such as wave mode, intensity level and session time. Intensity is set on a scale of 10 levels, allowing the treatment to be adapted to the area and to the tolerance of the person receiving the session.
The device includes start and pause functions to control emission during the session. The default time is 30 minutes, with indicative working durations of 10 to 20 minutes for facial sessions and 20 to 60 minutes for body sessions, always within professional, protocol-based use.
Three probes for facial and body work
The set includes three radiofrequency probes: a 7 cm body probe, a 4 cm facial probe and a cone-shaped probe for the eye area. This configuration allows the appropriate accessory to be selected according to the working surface and the type of area to be treated.
- Body probe 7 cm, for larger surface areas.
- Facial probe 4 cm, for facial work.
- Eye probe Cone-shaped, for contour areas.
- Return plate Included for monopolar operation of the device.
Wave modes and adjustable intensity
The device can operate with continuous, pulsed and combined wave modes. These modes provide different emission patterns to adapt the session to areas with different surface and thickness characteristics. Intensity adjustment should be progressive, checking tolerance throughout the treatment and following the device’s professional use guidelines.
Monopolar radiofrequency is based on the passage of current between the active electrode and the return plate, closing the circuit through the working area. For this reason, correct placement of the plate, selection of the head and protocol-based application are essential aspects for appropriate professional use.
Included accessories
- Main unit Weelko HighTech Smooth WKB003 device.
- Body probe 7 cm head.
- Facial probe 4 cm head.
- Eye probe Cone-shaped head.
- Return plate Accessory required for monopolar work.
- Connection cable Included.
Technical specifications
- Brand Weelko
- Model HighTech Smooth
- Reference WKB003
- Device type Digital monopolar radiofrequency device with touchscreen
- Intended use Facial and body beauty treatments
- Frequency 0.5 MHz
- Working power 160 W
- Rated power 140 W
- Input voltage 200-240 V
- Input frequency 50/60 Hz
- Screen 7-inch touchscreen
- Intensity levels 10 levels
- Wave modes Continuous, pulsed and combined
- Default time 30 min
- Indicative facial session 10-20 min
- Indicative body session 20-60 min
- Device dimensions 34 x 38 x 15 cm
- Net weight 8 kg
- Packaging dimensions 51 x 45 x 22 cm
- Gross weight 9 kg
- Low Voltage Directive 2014/35/EU
- EMC Directive 2014/30/EU
Professional use and start-up
The device is connected from the rear panel, where the power supply, radiofrequency probes and return plate are plugged in. Once switched on, the treatment is selected from the screen by choosing facial or body mode, wave type, intensity level and session time.
To preserve the accessories and prevent damage, the probes should be placed in their holder or rear support structure when not in use. The screen may be protected by a thin adhesive film intended to prevent marks during packaging and transport; it can be removed after unpacking where appropriate.
Professional application recommendations
Intensity adjustment should begin at low levels and be increased progressively according to the working area and the tolerance of the person receiving the session. During the treatment, it is advisable to maintain constant communication and monitor the thermal sensation, avoiding static applications or excessive dosing.
This device is intended for professional beauty use. It must be operated by trained personnel, following the working protocol, safety guidelines and the contraindications applicable to aesthetic radiofrequency.